The main business of the company is: bladder accumulator, Diaphragm accumulator, Piston Type Accumulator, oxygen cylinder, CO2 cylinder, gas cylinder, nitrogen gas cylinder, Welcome to inquire and negotiate cooperation by phone.
About    |    Contact

News

What is the reason for the failure of the accumulator? Pressure loss is a common cause!

Accumulators are important components in hydraulic systems used to store hydraulic energy, so their failure may have a negative impact on system performance. The following are some common reasons that may cause accumulator failure, including pressure loss:
Material fatigue: The material of the accumulator will be subjected to stress during the cyclic charging and discharging pressure process, which may lead to material fatigue. Over time, this can cause the diaphragm or wall of the accumulator to fail.
Pressure loss: Excessive or inappropriate working pressure may cause pressure loss in the accumulator. This may be caused by leakage, sealing issues, or other system issues. Pressure loss will reduce the performance of the accumulator and its energy storage capacity.
Leakage: Over time, the sealing components of the accumulator may wear or age, leading to liquid or gas leakage. Leakage can cause pressure loss and reduce the efficiency of the accumulator.
External damage: The accumulator may be damaged by external environmental factors such as impact, vibration, or chemical exposure. These damages may damage the diaphragm or container, leading to the failure of the accumulator.
Improper use: Improper operation or maintenance may cause the accumulator to fail. For example, excessive charging, frequent charging and discharging, or inappropriate temperature conditions may have adverse effects on the accumulator.

Extended use: Accumulators have a certain lifespan, and their performance may decrease over time. Periodic replacement and maintenance are crucial for extending the lifespan of the accumulator.
Maintaining and regularly inspecting hydraulic accumulators is crucial to ensuring their reliability and performance. Pressure loss is usually an indicator of accumulator problems, so it is important to regularly check and test the working pressure of the accumulator in the system. If problems are found, taking appropriate measures early can avoid more serious failures and ensure the safety and reliability of the system.